Acid Etching Revisited

January 25, 2016

During my last blog on January 10, 2016 about “Surface Preparation When Installing Concrete” we discussed among other things preparation of concrete by acid etching. I want to revisit that now in a slightly less formal explanation about why it is not the best of the possible methods of doing surface preparation.

Acid etching does not remove most contamination from the concrete. It is necessary before you acid etch concrete to remove most typical type of contamination like oil, grease, paint, mastic, and a host of other things first.

Acid etching attacks the Portland Cement. The Portland cement is the “glue” that is holding your concrete together. So acid etching done incorrectly will do more damage than good. Even if you do it correctly your floor may not be as strong a substrate for epoxy (or anything else) than it would have been if you mechanically cleaned it.

If you are going to acid etch I suggest that you not only do it properly but follow it with abrasive cleaning, to remove the soft top part of your concrete that is damaged by the acid etching. When I was an installer of epoxy products I rarely if ever acid etched but instead did mechanical cleaning.

Here are some of the reasons acid etching may not be desirable for your job.

  1. Acid etching is a risk to safety. Acid can damage items at your jobsite and pose a risk of injury to the people in the area.
  2. Mechanical cleaning is better for the environment, no acid will find its way into the ecosystem.
  3. Mechanical cleaning allows quicker turnaround time, you don’t have to wait overnight for the substrate to dry.
  4. Mechanical cleaning gives you more consistently high quality substrate than acid etching does.

In summary, whenever you can use abrasive cleaning it is safer and better than acid etching.

Please email me your questions to norm@epoxy.com or visit our website at www.epoxy.com


Selecting the Right Floor for a Mechanical Room

July 27, 2015

Mechanical Room Floors are very unique in their use and conditions. You have to consider the installation environment and the function of the floor. Our Mechanical Room Floor will protect the concrete, and contain any liquids that spill.

Systems used in mechanical rooms should be zero VOC. You do not want solvent evaporating from your material. Evaporated solvent could be picked up by your air handling unit sending it through your building. The best way to prevent this is with a VOC free 100% solids resin system. A resin system that is 100% solids has no solvent (or water) in it. It also means when you spread a gallon of material on your floor after it hardens you still have a gallon of material. With water-based and solvent based materials you lose half the material to evaporation.

Mechanical rooms should be chemical resistant. Typically they are top coated with Epoxy.com Product #2 Chemical Resistant Epoxy – www.epoxy.com/2.aspx. If it is a chemical feed room you can supply a list of chemicals and concentrations to the technical support department so you can make sure the #2 is chemical resistant enough.

The systems used for mechanical rooms are impact resistant. The limiting factor is the strength of the concrete substrate. Properly installed the epoxy will stay bonded to the concrete. The only way the epoxy can chip is if you chip the concrete from underneath the epoxy. You can install a thicker epoxy floor for an additional cost if you think you need still additional protection.

The systems recommend for mechanical rooms are highly abrasion resistant and will easily handle traffic up to heavy fork lift traffic. The system can be made even thicker if you have an unusual amount of abusive traffic.

When the mechanical room is over a finished space, it is suggested that a crack isolation membrane be integrated into the system. This can be done with Product #32 Epoxy Membrane System. The advantage of #32 Epoxy Membrane Resin as part of the system is 100% solids and has zero VOCs.

If the mechanical room is shut down and you can handle solvent and want something still more flexible you can use Epoxy.com Product #459 a two component, high solids, elastomeric urethane instead of or in addition to the Product #32 Epoxy Membrane above. Product #459 exhibits excellent elongation properties along with high tensile strength and tear resistance to make it an ideal crack resistant membrane for use under Product #2 and all of our other epoxy mechanical room floor coatings.

One of the primary reasons you need a mechanical room floor over finished space below is to waterproof it. The above methods accomplish the waterproofing in the center of the floor. The edges of the floor can be protective with a coving material up the wall and around pipe penetrations. That can be accomplished with Product #720 Epoxy Coving Resin System which can be used to install an integral cove base for all of our epoxy based mechanical room flooring and most of our other epoxy flooring and coating systems. This provides seamless wall to floor protection.

For more information on seamless water and chemical resistant mechanical room flooring, contact Epoxy.com Technical Support Department at 352-533-2167, or email me at norm@epoxy.com.

 


Waterproofing of Leaking Foundations

May 4, 2015

This is the time of year when the ground thaws and basements leak. If you are one of those building owners, here are some earlier posts that you will find useful.

  1. http://news.epoxy.com/2014/09/04/epoxy-waterproof-block-wall-foundation/
  2. http://news.epoxy.com/2014/09/15/shows-how-to-identify-leaks-that-need-waterproofing-in-basement-walls-and-floors-that-are-made-out-of-poured-concrete-part-2b-will-deal-with-the-actual-repairs-to-poured-concrete-leaks/
  3. http://news.epoxy.com/2014/09/18/epoxy-injection-repairs-of-cracks-in-poured-concrete/

Easier to Navigate Epoxy.com

April 10, 2015

We are pleased to announce our new easy to navigate links on http://www.epoxy.com/. Thanks to our loyal customer’s feedback we have upgraded our website to make it easier to find products, installation techniques and important documents for your needs.

 

Our website at http://www.Epoxy.com has been upgraded at the top of the page to read more like a book. Making it user friendly for all. Whether you are an existing customer looking for a product that you are already using or a new visitor to our website looking for ideas to start your projects, we have made it easier for you to navigate.

 

 

Existing customers still have access to our catalogue of products by clicking the Products Catalogue link directly after our Home Page link. If you are new to our website or if you have a new project idea or customers looking for something you have not done previously we have links with drop down boxes to assist you in finding the Right Products for the Right Job.

We have added quick links at the top of any page that shows up as an error. You can now type in a saved page directly and if you miss part of the page address or are not 100% certain of the destination, you will still be directed towards our top of the page links for you to navigate through our website.

Our website is customer recommended, updated, and we appreciate your feedback. If you see anything that would help you navigate our website better www.epoxy.com please contact Norm at 352-533-2167. We appreciate your feedback and are thankful for your suggestions.

As always you can contact our technical service department at 352-533-2167 for assistance as we still strongly believe in the human interface. Our customer service department is open Monday – Friday 9-4 ET for your orders and will be happy to help you.